75W Irteera bakarreko DIN Rail industrialaren elikadura-hornidura NDR-75 seriea
AC sarrera unibertsala / Gama osoa
Babesak: Zirkuitu laburra / Gainkarga / Tentsioa / Tenperatura gain
Aire konbekzio librearen bidez hoztea
DlN errailean instala daiteke TS-35/7.5 edo 15
UL 508 (Industrial Control Equipment} homologatua
EN61000-6-2 (EN50082-2} industria-immunitate maila
% 100eko karga osoa erretzeko proba
3 urteko bermea
EREDUA | NDR-75-12 | NDR-75-24 | NDR-75-48 |
DC TENTSIOA | 12V | 24V | 48V |
KORRONTE BALORATUA | 6.3A | 3.2A | 1.6A |
GAUR GUNEA | 0 ~ 6,3A | 0 ~ 3,2A | 0 ~ 1,6A |
POTENTZIA NOMINATUA | 75,6 W | 76,8 W | 76,8 W |
RIPPLE & NOISE (gehienez) Oharra.2 | 80mVp-p | 120mVp-p | 150mVp-p |
TENTSIOA ADJ.BARRUTA | 12 ~ 14V | 24 ~ 28V | 48 ~ 55V |
TENTSIO-TOLERANTZIA Oharra.3 | ±% 2,0 | ±% 1,0 | ±% 1,0 |
LERRO ARAUDIA | ±% 0,5 | ±% 0,5 | ±% 0,5 |
ZARGA ERREGULAZIOA | ±% 1,0 | ±% 1,0 | ±% 1,0 |
KONFINIZIOA, IGOERA DENBORA | 1200ms, 60ms/230VAC 2000ms, 60ms/115VAC karga osoan | ||
ETENTZEKO DENBORA (Tip.) | 60ms/230VAC 12ms/115VAC karga osoan | ||
TENTSIO-ESTOREA Oharra.6 | 90 ~ 264VAC 127 ~ 370VDC [DC sarrerako funtzionamendua posible da AC/L(+), AC/N(-) konektatuz] | ||
MAIZTASUN BARRUTA | 47 ~ 63Hz | ||
ERAGINKORTASUNA (Tip.) | %85,50 | %88 | %89 |
Korronte alternoa (tipoa) | 1.45A/115VAC 0.9A/230VAC | ||
SARRERAKORRONTEA (Tip.) | 20A/115VAC 35A/230VAC | ||
ISURTASUN KORRONTEA | <1mA / 240VAC | ||
GAINKARGA | 105 ~ 130% irteerako potentzia nominala | ||
Babes mota: Korronte konstantea mugatzea, automatikoki berreskuratzen da matxura egoera kendu ondoren | |||
GAINEKO TENTSIOA | 14 ~ 17V | 29 ~ 33V | 56 ~ 65V |
Babes mota: itzali o/p tentsioa, piztu berriro berreskuratzeko | |||
TENPERATURA GAINEKOA | Babes mota: itzali o/p tentsioa, piztu berriro berreskuratzeko | ||
LAN TEMP. | -20 ~ +70 ℃ (Ikusi "Derating Kurba") | ||
LANEKO HEZETASUNA | 20 ~ 95% RH kondentsaziorik gabekoa | ||
BILTEKETA TENPERATURA, HEZETASUNA | -40 ~ +85 ℃, % 10 ~ 95 RH | ||
TEMP.KOEFIZENTEA | ±0,03%/℃ (0 ~ 50 ℃) | ||
BIBRAZIOA | Osagaia: 10 ~ 500Hz, 2G 10min./1ziklo, 60min.bakoitza X, Y, Z ardatzetan zehar;Muntaketa: IEC60068-2-6 betetzea | ||
SEGURTASUN ESTANDARRAK | UL508, TUV EN62368-1, EAC TP TC 004 homologatuta; (EN60204-1 bete) | ||
JANTSI TENTSIOA | I/PO/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||
ISOLAKETA ERRESISTENTZIA | I/PO/P, I/P-FG, O/P-FG:> 100 M ohmios / 500 VDC / 25 ℃/ % 70 RH | ||
EMC ISURPENA | EN55032 (CISPR32), EN61204-3 B Klasea, EN61000-3-2,-3, EAC TP TC 020 betetzea | ||
EMC IMMUNITATEA | EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, industria astuneko maila, A irizpideak, EAC TP TC 020 betetzea | ||
MTBF | 486,2K ordu min.MIL-HDBK-217F (25 ℃) | ||
DIMENTSIOA | 32*125,2*102 mm (W*H*D) | ||
PAKETARA | 0,51Kg;28 pieza/15,3Kg/1,22CUFT | ||
OHAR |
| ||
1. Bereziki aipatzen ez diren parametro guztiak 230VAC sarreran, karga nominalean eta giro-tenperaturan 25 ℃ neurtzen dira. 2. Uhina eta zarata 20MHz-ko banda-zabaleran neurtzen dira 0.1uf eta 47uf-ko kondentsadore paralelo batekin amaitzen den 12"-ko pare bihurritu bat erabiliz. 3. Tolerantzia: konfigurazio-perdoia, lerro-erregulazioa eta karga-erregulazioa barne hartzen ditu. 4. Elikatze-hornidura azken ekipo batean instalatuko den osagaitzat hartzen da.Azken ekipoak EMC zuzentarauak betetzen dituela berretsi behar da berriro. |